1838 Uppsatser om Heat load characteristics - Sida 1 av 123

Inventering av värmelager för kraftvärmesystem

When a combined heat and power plant produces heat and power it often faces a deficit of heat load during the summer or other periods of time. This heat is often unnecessarily cooled away or the power production has to be reduced or shut off. If it is possible to store heat from periods with low heat demand to periods with high heat demand one can get many benefits. Among these benefits are: increased power production, decreased operation with partial load, uniformly distributed load.To be able to store heat in situations like this long-term thermal heat storages are needed. In this thesis five different types of stores are presented: rock cavern storage, tank storage, pit water storage, borehole storage and aquifer storage.

Utveckling av lastmodell för Uppsala fjärrvärmenät

The aim of this study was to develop a load prognosis model for Uppsala district heating system to be used as a tool for heat production optimization. The methodwas to build three models for the different customer types; housing, industry andoffices and then scale them for the total system using data from Uppsala districtheating system. The heat load consists of two parts, one that is temperaturedependent and one that is dependent of the social behavior of the customers. Thetemperature part was modelled with an ARX model using an outdoor temperatureprognosis as input signal. The social behavior part was modelled using the mean ofthe social behavior from some days before and additionally by distinguishing betweenweekdays and weekends.

Kylapotentialen i Drefviken för Vattenfall Heat AB

Vattenfall Heat AB is a district heat provider in Drefviken, but has yet to establish any cooling systems in this area. This thesis examines the potential client base within the area today and over the coming 20 years. The feasibility of the most common cooling technologies is evaluated and results show a total potential for an installed capacity of 30 MW providing 50 GWh of cooling per year. One of the examined areas shows good prospect for heat driven absorption chillers during the summer months when the heat load is limited..

Spillvärmeåtervinning

SAPA´s resource of waste heat is the basis for this thesis to investigate the possibility of energy assets in their cooling water and possible uses for it. The energy in the waste water is greater than the current need which has three uses which are (1) heating the factory, (2) converting liquid propane to propane gas and (3) local domestic heating. The average energy load that is available is 1, 7 MW and the average temperature in the cooling water is 41°C. The total energy load at dimensioning out side temperature is approximately 1,6 MW for the three current uses. The temperature is currently too low to be used directly in the existing systems so an upgrade is needed.

Metoder för lastprioritering i fjärrvärmecentraler

A problem in the field of district heating is the oil burners needed to provide power when a peak load occurs. One possible way of reducing the needed amount of oil is to reduce the power demand for space heating in the district-heating substations when the need for district heating water exceeds a certain limit. This can be done by use of a locally working controller function.In this Thesis the options concerning load priority are evaluated. To evaluate the potential for using controller functions concerning peak load priority an experiment was brought out in a chosen district-heating substation. The impact on the indoor thermal comfort during a heat reduction was also taken into account.

Kyla i Nyköping och Motala : Kartläggning av kylapotential för Vattenfall Värm

The Swedish energy company Vattenfall is currently the owner of the district heatingsystems in Nyköping and Motala. To be able to also offer cooling solutions tocustomers are becoming more and more important. This report describes the resultsof an investigation of the cooling market in the two cities and the potential needs forcooling today and in the coming 20 years. The total potential for the coming 20 yearsis estimated to be roughly 17 MW for Nyköping and 9 MW for Motala.Two possible district cooling systems for each of the two city centers was modeledand a comparison was made between different cooling techniques namely absorptionand compressor chillers.Absorption chillers driven with district heating during the summer is one way ofincreasing the load in a combined heat and power plant and thereby the possibleelectricity generation. The cost of heat production must be low for absorption chillerto be able to compete as an alternative.

Äldreboendet på Zakrisdal : En studie om solvärme med säsongslagring

A home for elderly is planed to be built at Zakrisdal, Karlstad, Sweden. The heat source for the building was at the time not determined. In order by the local government of Karlstad this report is meant to examine if the need of heat could be provided only by solar heat combined with a seasonal heat storage. The problem to solve is, if the need of heat from the home for elderly is provided from only solar heat, whitch dimensions of the solar collectors and the storage is needed?.

Vibrationsdämpning av värmepump

Thermia Värme AB is one of the market leading manufactures of heat pumps. In order tomaintain this position, the company wants to improve the vibration characteristics of theirproducts. The aim of this thesis is to develop product design changes that lead to a reductionof vibrations in the heat pump Thermia Diplomat 8.The main cause for vibrations in the system is flow pulsation and mechanical forces inducedby the scroll compressor. Vibration is transmitted through the compressor piping and receivedby the heat exchangers, from where it is further transmitted to the connection points for theradiator and heat source circuits.A number of design changes in order to improve the vibration characteristics have beenevaluated through calculations and practical experiments. The changes have included thecompressor and heat exchanger mountings, the compressor suction and discharge line pipingand also pulsation dampening.The results of the experiments show that the vibration levels in the connections for the heatingand brine circuits can be decreased strikingly through changes in suction and discharge linepiping.

Norrkila arena : visuell beskrivning av arena

A home for elderly is planed to be built at Zakrisdal, Karlstad, Sweden. The heat source for the building was at the time not determined. In order by the local government of Karlstad this report is meant to examine if the need of heat could be provided only by solar heat combined with a seasonal heat storage. The problem to solve is, if the need of heat from the home for elderly is provided from only solar heat, whitch dimensions of the solar collectors and the storage is needed?.

Högtempererat borrhålslager för fjärrvärme

The district heating load is seasonally dependent, with a low load during periods of high ambient temperature. Thermal energy storage (TES) has the potential to shift heating loads from winter to summer, thus reducing cost and environmental impact of District Heat production. In this study, a concept of high temperature borehole thermal energy storage (HT-BTES) together with a pellet heating plant for temperature boost, is presented and evaluated by its technical limitations, its ability to supply heat, its function within the district heating system, as well as its environmental impact and economic viability in Gothenburg, Sweden, a city with access to high quantities of waste heat.The concept has proven potentially environmentally friendly and potentially profitable if its design is balanced to achieve a good enough supply temperature from the HT-BTES. The size of the heat storage, the distance between boreholes and low borehole thermal resistance are key parameters to achieve high temperature. Profitability increases if a location with lower temperature demand, as well as risk of future shortage of supply, can be met.

Sammankoppling av fjärrvärmenäten i Nyköping och Oxelösund : miljö- och systemkonsekvenser

District heating covers most of the residential areas and industries in the twoneighbouring Swedish municipalities Nyköping and Oxelösund. In Nyköping,Vattenfall AB Värme produces heat in a bio-fuelled CHP plant. In Oxelösund,waste heat and use of waste gases from the steel production at SSABOxelösund is the basis in the district heating system.This report examines the environmental consequences of a connection betweenthe two district heating systems. A broad system approach is used and the focusis on environmental effects in the system.A system analysis has been performed on the result of simulations of differentheat and electricity production alternatives. The alternatives simulated wereone where Vattenfall Nyköping covers the base load in the joint district heatingsystem and two where the power plant at SSAB Oxelösund supplies the heatbase load.The conclusion in this report is that the consequences of connecting the twodistrict heating systems can be both positive and negative, depending onsystem boundaries and on the environmental focus.

Ökad resurseffektivitet i kraftvärmesystem genom säsongslagring av värme

Increased resource efficiency in an energy system could result in large economic and environmental benefits. Tekniska verken i Linköping AB (Tekniska verken) is responsible for the district heating network in Linköping. Their vision is to create the world?s most resource efficient region. An important step towards this vision is more efficient usage of produced heat, something which could be achieved through integration of a seasonal heat storage in the energy system.

Frånluftsvärmepumpens möjligheter i flerbostadshus

If a building is heated by a heat pump, it is of high importance that the heat pump has a high coefficient of performance. An exhaust air heat pump extracts heat from the building?s exhaust air. The air has a relatively high and constant temperature all year around, leading to a high seasonal coefficient of performance. This thesis examines whether it is profitable to complement an exhaust ventilation system with an exhaust air heat pump in an apartment block that already has geothermal heat pump, district heating, oil- or biofuel heated system.

En systemlösning för en framtida fjärrvärmeutbyggnad i Täby : ur Fortum Värmes perspektiv

At the moment in central Täby there are small district heating network operated by Fortum Heat. The distribution network has an annual heat demand of about 70 GWh, which is supported by the network's two plants, Galten and Farmen. Täby as a region is rapidly growing and there are grand plans to develop the area. Estimated market potential for a future district heating expansion in Täby is very high and as early as in 2007 Täby decided to invest in a large-scale expansion. In autumn 2009 Täby did a procurement process, known as the ?Täby initiative?, to find a partner that could implement those expansion plans. To secure a cheap basic production the partner also need to build a power plant at Hagby recycling center. Despite high interest during initial state of the process, only one procurement offer were received and Täby suspended the contract in March the following year.

Värmeöverföring i bergvärmesystem : En numerisk analys av den ringformade koaxiala borrhålsvärmeväxlaren

The borehole heat exchangers of today suffer from poor thermal and hydrodynamic performance. The purpose of this thesis is to improve the performance of ground source heat pump systems and thermal energy storages by increasing the energy efficiency of the borehole heat exchangers. For this reason, the annular coaxial borehole heat exchanger (CBHE) has been analyzed. This type of heat exchanger is interesting in terms of both thermal and hydrodynamic performance. A model has been set up in the program Comsol Multiphysics in order to investigate the heat transfer characteristics along the borehole.